FRIULAIR has increased it’s range of compressed air dryers with the introduction of the new ACT range (Aluminium Cooling Technologies). This high efficiently cooling module has a direct effect on reducing energy consumption and pressure drop.
The main advantages are: low pressure drop even with load variances and a constant pressure DewPoint with differing load conditions.

The components of the ACT range from refrigerant to materials of construction have been selected with maximum respect for the environment and their ability to be recycled.

All accessories of this range
 
 
Data in the table refer to the nominal condition and max. working condition written to flank.

Upon request water-cooled version from model ACT 55 included (Max. water temperature 30°C).


Nominal ambient temperature:  25°C
Inlet air:  at 7 barg and 35°C
Pressure DewPoint:  3°C (-22°C atm. pressure DewPoint)
 Max. working condition
Ambient temperature:  45°C
Inlet air temperature:  55°C
Inlet air pressure:  at 14 barg
 
Model Refrig. Flow Rate Pressure
drop
Connections Power Supply Dimensions [mm]
Nl/min Nm³/h scfm bar Ø IN-OUT Ph/V/Fr A B C D E F G
ACT 3 R134.a
350
21 12
0.01
G1/2"BSP-F
1/230-240/50
345 420 740 158 56 700 770
ACT 5 R134.a 550 33 19 0.02 G1/2"BSP-F 1/230-240/50 345 420 740 158 56 700
770
ACT 8 R134.a 850 51 30 0.04 G1/2"BSP-F 1/230-240/50 345 420 740 158 56 700 770
ACT 12 R134.a 1.200 72 42 0.06 G1/2"BSP-F 1/230-240/50 345 420 740 158 56 700 770
ACT 18 R134.a 1.800 108 64 0.07 G1"BSP-F 1/230-240/50 485 455 785 130 69 705
825
ACT 23 R134.a 2.300 138 81 0.10 G1"BSP-F 1/230-240/50 485 455 785 130 69 705 825
ACT 30 R404A 3.100 186 109 0.10 G1.1/4"BSP-F 1/230-240/50 485 455 785 130 69 705 825
ACT 40 R404A 4.000 240 141 0.19 G1.1/4"BSP-F 1/230-240/50 485 455 785 130 69 705 825
ACT 55 R404A 5.500 330 194 0.13 G1.1/2"BSP-F 1/230-240/50 555 580 885 135 85 800
940
ACT 60 R404A 6.200 372 219 0.16 G1.1/2"BSP-F 1/230-240/50 555 580 885 135 85 800 940
ACT 80 R404A 8.100 486 286 0.08 G2"BSP-F 1/230-240/50 555 625 975 245 100 865 1.035
ACT 100 R404A 10.500 630 371 0.13 G2"BSP-F 1/230-240/50 555 625 975 245 100 865 1.035
ACT 120 R404A 12.500 750 441 0.08 G2.1/2"BSP-F 1/230-240/50 665 725 1.105 375 190 930 1.155
ACT 140 R404A 14.500 870 512 0.11 G2.1/2"BSP-F 1/230-240/50 665 725 1.105 375 190 930 1.155
ACT 160 R404A 16.000 960 565 - G2.1/2"BSP-F 1/230-240/50 665 725 1.105 375 N.A. 930 N.A.
ACT 80 3~ R404A 8.100 486 286 - G2"BSP-F 3/400-415/50 N.A. N.A. N.A. N.A. N.A. N.A. N.A.
ACT 100 3~ R404A 10.500 630 371 - G2"BSP-F 3/400-415/50 N.A. N.A. N.A. N.A. N.A. N.A. N.A.
ACT 120 3~ R404A 12.500 750 441 - G2.1/2"BSP-F 3/400-415/50 665 725 1.105 375 N.A. 930 N.A.
ACT 140 3~ R404A 14.500 870 512 - G2.1/2"BSP-F 3/400-415/50 665 725 1.105 375 N.A. 930 N.A.
ACT 160 3~ R404A 16.000 960 565 - G2.1/2"BSP-F 3/400-415/50 665 725 1.105 375 N.A. 930 N.A.
ACT 180 R404A 18.000 1.080 636 0.12 DN80-PN 16 3/400-415/50 785 950 1.410 500 220 1.155 1.500
ACT 210 R404A 21.000 1.260 742 0.18 DN80-PN 16 3/400-415/50 785 950 1.410 500 220 1.155 1.500
ACT 250 R404A 25.000 1.500 883 0.10 DN80-PN 16 3/400-415/50 785 950 1.410 500 220 1.155 1.500
ACT 300 R404A 30.000 1.800 1.060 0.17 DN80-PN 16 3/400-415/50 785 950 1.410 500 220 1.155 1.500
ACT 360 R404A 36.800 2.208 1.300 - DN80-PN 16 3/400-415/50 785 1.150 1.410 500 N.A. 1.155 N.A.
ACT 400 R404A 40.000 2.400 1.413 0.19 DN100-PN 16 3/400-415/50 1.005 1.400 1.610 330 N.A. 1.410 1.955
ACT 500 R404A 50.000 3.000 1.766 0.11 DN100-PN 16 3/400-415/50 1.005 1.400 1.610 330 N.A. 1.410 1.955
ACT 600 R404A 60.000 3.600 2.119 0.19 DN100-PN 16 3/400-415/50 1.005 1.400 1.610 330 N.A. 1.410 1.955
ACT 720 R404A 73.600 4.416 2.600 - DN125-PN 16 3/400-415/50 1.005 1.400 1.610 330 N.A. 1.410 N.A.
ACT 900 R404A 90.000 5.400 3.178 0.19 DN150-PN 16 3/400-415/50 1.550 2.200 1.680 380 N.A. 1.470 N.A.
ACT 1200 R404A 120.000 7.200 4.238 0.19 DN150-PN 16 3/400-415/50 1.550 2.200 1.680 380 N.A. 1.470 N.A.
ACT 1500 R404A 150.000 9.000 5.297 0.19 DN200-PN 16 3/400-415/50 1.550 2.650 1.730 380 N.A. 1.510 N.A.
ACT 1800 R404A 180.000 10.800 6.357 0.19 DN200-PN 16 3/400-415/50 1.550 3.020

1.730

380 N.A. 1.510 N.A.
- Friulair S.r.l. reserves the right to modify, in any moment technical details without notice -
Correction factor for operating pressure changes
 Inlet air pressure [barg] 4 5 7 8 10 12 14
 Factor 0.77 0.85 1.00 1.06 1.15 1.21 1.25
Correction factor for ambient temperature changes
 Ambient temperature [C°] 25 30 35 40 45
 Factor 1.00 0.98 0.95 0.90 0.80
Correction factor for inlet air temperature changes
 Air temperature [C°] 30 35 40 45 50 55
 Factor 1.20 1.00 0.85 0.75 0.61 0.49
Correction factor for DewPoint changes
 DewPoint [C°] 3 5 7 10
 Factor 1.00 1.09 1.18 1.38