PLH series (high pressure dryers for compressed air systems up to 50 barg) makes the most of manufacturing and functional advantages of brazed plate heat exchangers, which are more suitable for high pressure working conditions (on models PLH 15-500). All the stainless steel plate heat exchangers used are manufactured by primary companies and are specifically designed for air dryer applications and certified for high pressure (up to 50 barg). The refrigerant circuit and demister type condensate separator are projected and dimensioned to increase dryer performance, and comply to the 97/23/CE-PED directive.

Main characteristic are:
1. simple and ergonomic component layouts guarantee functionality and efficiency;
2. final performance is excellent due to low pressure drop and to constant pressure DewPoint;
3. dryer design is very attractive both aesthetically with a two tone cabinet and practically with a rounded profiles robust casing (on models PLH 15-330).

All accessories of this range
 
 
Data in the table refer to the nominal condition and max. working condition written to flank.


Nominal ambient temperature:  25°C
inlet air temperature:  35°C
inlet air pressure:  40 barg
Pressure DewPoint:  3°C
 Max. working condition
Ambient temperature:  45°C
Inlet air temperature:  65°C
Inlet air pressure:  at 50 barg
   
Model Weight Flow Rate Connections Power Supply Dimensions [mm] Refrig.
Kg Nl/min Nm³/h scfm Ø IN-OUT Ph/V/Fr A B C Type
PLH 4 C
28
417
25
15
G 3/8" BSP - F
1/230-240/50
370 450 445 R134.a
PLH 8 C 29 800 48 28 G 3/8" BSP - F 1/230-240/50 370 450 445 R134.a
PLH 12 C 32 1.200 72 42 G 3/8" BSP - F
1/230-240/50
370 450 445 R134.a
PLH 15 36 1.500 90 53 G 1/2" BSP - F 1/230-240/50 350 490 610 R134.a
PLH 22 37 2.250 135 80 G 1/2" BSP - F 1/230-240/50 350 490 610 R134.a
PLH 30 54 3.000 180 106 G 3/4" BSP - F 1/230-240/50 510 625 830 R404.A
PLH 40 59 4.000 240 141 G 3/4" BSP - F 1/230-240/50 510 625 830 R404.A
PLH 50 61 5.250 315 186 G 1" BSP - F 1/230-240/50 510 625 830 R404.A
PLH 75 87 7.500 450 265 G 1" BSP - F 1/230-240/50 560 725 870 R404.A
PLH 100 109 10.250 615 362 G 1" BSP - F 1/230-240/50 560 725 870 R404.A
PLH 130 119 13.500 810 477 G 1.1/2" BSP - F 1/230-240/50 580 655 1.240 R404.A
PLH 160 132 16.800 1.008 594 G 1.1/2" BSP - F 3/400-415/50 580 655 1.240 R404.A
PLH 200 232 20.000 1.200 707 G 2" BSP - F 3/400-415/50 610 1.155 1.700 R404.A
PLH 270 238 27.000 1.620 954 G 2" BSP - F 3/400-415/50 610 1.155 1.700 R404.A
PLH 330 260 33.500 2.010 1.184 G 2" BSP - F 3/400-415/50 610 1.155 1.700 R404.A
PLH 400 430 40.500 2.430 1.431 FL. ANSI2.1/2" 3/400-415/50 1.380 1.400 1.610 R404.A
PLH 500 450 50.500 3.030 1.784 FL. ANSI2.1/2" 3/400-415/50 1.380 1.400 1.610 R404.A
- Friulair S.r.l. reserves the right to modify, in any moment technical details without notice -
Correction factor for operating pressure changes
 Inlet air pressure [barg] 15 20 25 30 35 40 45 50
 Factor 0.75 0.81 0.87 0.92 0.96 1.00 1.03 1.06
Correction factor for ambient temperature changes
 Ambient temp. [C°] 25 30 35 40 45
 Factor 1.00 0.98 0.95 0.90 0.80
Correction factor for inlet air temperature changes
 Air temperature [C°] 30 35 40 45 50 55 60 65
 Factor 1.14 1.00 0.84 0.73 0.62 0.54 0.46 0.41
Correction factor for DewPoint changes
 DewPoint [C°] 3 5 7 10
 Factor 1.00 1.09 1.18 1.38