The TDF range of high capacity compressed air dryers from FRIULAIR cover flow rates from 80.000 Nl/min to 200.000 Nl/min.

The main characteristics are:
1. Compact;
2. Clear layout of internal components for ease of maintenance;
3. Robust powder coated galvanized casings with easy access.

Option of either a water-cooled or an air-cooled condenser.
The DMC20 control panel is designed to access and calibrate the operating conditions of the dryer.

All accessories of this range

 
 
Data in the table refer to the nominal condition and max. working condition written to flank.



Nominal ambient temperature:  25°C
Nominal inlet air pressure:  at 7 barg and 35°C
Pressure DewPoint:  3°C (-22°C atm. pressure DewPoint)
 Max. working condition
Ambient temperature:  45°C
Inlet air temperature:  45°C
Inlet air pressure:  at 12 barg
Water temperature:  30°C
 
AIR COOLED
Model Refrig. Flow Rate Connections Power supply Dimensions [mm] Weight
Nl/min Nm³/h scfm Ø IN-OUT Ph/V/Fr A B C D E F G Kg
TDF 800/AC R404A 80.000 4.800 2.824 DN125 PN16 3/400/50 850 2.450 1.665 415 540 600 1.800 1.200
TDF 1100/AC R404A 110.000 6.600 3.883 DN150 PN16 3/400/50 850 2.450 1.665 415 540 600 1.800
1.280
TDF 1500/AC R404A 150.000 9.000 5.295 DN200 PN16 3/400/50 1.400 2.600 1.700 320 550 600 - 1.880
TDF 2000/AC
R404A
200.000
12.000
7.060
DN200 PN16
3/400/50
1.400 2.600 1.700 320 550 600 - 1.930
- Friulair S.r.l. reserves the right to modify, in any moment technical details without notice -
WATER COOLED
Model Refrig. Flow Rate Connections Power supply Dimensions [mm] Weight
Nl/min Nm³/h scfm Ø IN-OUT Ph/V/Fr A B C D E F G Kg
TDF 800/WC R404A 80.000 4.800 2.824 DN125 PN16 3/400/50
850 2.450 1.665 415 540 600 -

1.150

TDF 1100/WC R404A 110.000 6.600 3.883 DN150 PN16 3/400/50 850 2.450 1.665 415 540 600 - 1.230
TDF 1500/WC R404A 150.000 9.000 5.295 DN200 PN16 3/400/50 1.400 2.600 1.700 320 550 600 - 1.800
TDF 2000/WC
R404A 200.000
12.000
7.060
DN200 PN16
3/400/50 1.400 2.600 1.700 320 550 600 - 1.850
- Friulair S.r.l. reserves the right to modify, in any moment technical details without notice -
Correction factor for operating pressure changes
 Inlet air pressure [barg] 4 5 6 7 8 9 10 11 12
 Factor 0.77 0.85 0.93 1.00 1.06 1.11 1.15 1.18 1.21
Correction factor for ambient temperature changes
 Ambient temperature [C°] 25 30 35 40 45
 Factor 1.00 0.98 0.95 0.90 0.80
Correction factor for inlet air temperature changes
 Air temperature [C°] 30 35 40 45
 Factor 1.20 1.00 0.82 0.67
Correction factor for DewPoint changes
 DewPoint [C°] 3 4 5 6 7 8 9 10
 Factor 1.00 1.02 1.05 1.07 1.10 1.12 1.15 1.18