Back to the product list

Heatless Adsorption Dryers HDT Series

Flow rate: 19 ÷ 9 060 m3/h

The HDT range is used in situations where a refrigeration dryer dew point is insufficient under ISO 8573.1.

The HDT range is used in situations where a refrigeration dryer dew point is insufficient under ISO 8573.1. This includes electronics, pharmaceuticals, foodstuffs, pneumatic conveying industries, or in installations with low ambient temperatures. With its cold-regenerated adsorption dryer technology, a dew point down to -70°C can be achieved. These dryers consist of two parallel tanks filled with adsorbent material (molecular sieve): while one column dries the air, the other is regenerated with a small part of the already treated air. Units are equipped with an inlet de-oiling filter and an outlet anti-dust filter. The DDC15 electronic controller (industry 4.0 ready), available on the entire range, provides an intuitive interface for monitoring operation and scheduled maintenance. It manages time-based regeneration cycles (or using optional dew point probe).


MAXIMUM WORKING CONDITIONS

  • Ambient temperature: + 50°C
  • Inlet air pressure: 16 barg (HDT3÷25) / 10.3 barg
  • Inlet air temperature: + 50°C

Model

Air flow

Power Supply

Connections

[m3/h]

[l/min]

[scfm]

[Ph/Volt/Fr]

[ Ø ]

HDT 3

19

320

11

1/230/50-60

G 3/8” BSP-F

HDT 5

32

530

19

1/230/50-60

G 3/8” BSP-F

HDT 8

46

760

27

1/230/50-60

G 3/8” BSP-F

HDT 12

72

1 200

42

1/230/50-60

G ½” BSP-F

HDT 18

111

1 850

65

1/230/50-60

G ¾” BSP-F

HDT 25

150

2 500

88

1/230/50-60

G 1” BSP-F

HDT 30

180

3 000

106

1/230/50-60

G 1” BSP-F

HDT 40

234

3 900

138

1/230/50-60

G 1.1/2” BSP-F

HDT 50

300

5 000

177

1/230/50-60

G 1.1/2” BSP-F

HDT 60

372

6 200

219

1/230/50-60

G 1.1/2” BSP-F

HDT 75

450

7 500

265

1/230/50-60

G 1.1/2” BSP-F

HDT 90

540

9 000

318

1/230/50-60

G 1.1/2” BSP-F

HDT 130

768

12 800

452

1/230/50-60

G 2” BSP-F

HDT 160

972

16 200

572

1/230/50-60

G 2” BSP-F

HDT 200

1 230

20 500

724

1/230/50-60

G 2.1/2” BSP-F

HDT 250

1 530

25 500

901

1/230/50-60

G 2.1/2” BSP-F

HDT 300

1 800

30 000

1 060

1/230/50-60

DN80 PN16

HDT 350

2 160

36 000

1 272

1/230/50-60

DN80 PN16

HDT 400

2 520

42 000

1 484

1/230/50-60

DN80 PN16

HDT 450

2 736

45 600

1 611

1/230/50-60

DN100 PN16

HDT 620

3 750

62 500

2 208

1/230-240/50-60

DN125 PN16

HDT 800

4 860

81 000

2 862

1/230-240/50-60

DN150 PN16

HDT 1000

6 120

102 000

3 604

1/230-240/50-60

DN150 PN16

HDT 1200

7 560

126 000

4 452

1/230-240/50-60

DN150 PN16

HDT 1500

9 060

151 000

5 336

1/230-240/50-60

DN200 PN16

Data refer to the following nominal condition: inlet air pressure 7 barg; inlet air temperature +35 °C

  • Desiccant towers
  • Shuttle spool valve
  • Regeneration drain solenoid valve
  • Silencer
  • Regeneration nozzle
  • DDC15 Electronic Controller
  • Inlet oil filter (0.01 micron)
  • Outlet dust filter (1 micron)
  • Inlet filter condensate drain
  • Pressure switches – Fail to switch alarm (optional)
  • DewPoint meter (optional)
  • Upon request different Power Supply or pneumatic control dryers.
  • IP55 pressure switches to enable the “SWITCHING ALARM” function of the DDC15 instrument
  • pressure dew point meter, complete with cell and sampling system, interfaced with the DDC15 instrument. Includes instrument calibration certificate.
  • Pressure Switch Kit + Dew Point Meter.
  • CE certification for pressure tanks up to 16 Bar
  • Annual or 3000 hour maintenance kit / Two-year or 6000-hour maintenance kit / 3 year or 9000 hour desiccant material replacement kit