Back to the product list

CFT Series Water Chillers for Reliable Temperature Control

CHILLERS

from 100 to 300 kW

The CFT range consists on air cooled water chillers with axial fans...

The CFT range consists on air cooled water chillers with axial fans suitable for outdoor installations. The family comprises 8 models with cooling capacities ranging from 100 to 300 kW.

Frame and cabinet are made up of galvanized powder coated steel. This makes CFT suitable for outdoor installations and harsh environments.

All standardunits are equipped with:

  • Brazed stainless steel plates evaporator type
  • Water differential pressure switch
  • Inlet/outlet galvanized steel pipes.
  • Water strainer
  • Scroll type compressors
  • Aluminum microchannel condensers
  • Axial fans
  • Microprocessor controller
  • RS485 port

The hydraulic circuit is highly customizable according to customer’s requirements.

Units from CFT230 to CFT300 boast a double refrigeration circuit with one hydraulic circuit. T his configuration is very efficient with partial loads compared to independent evaporator versions.


EASY MAINTENANCE

The compressor cabinet is separate from the fan’s section and is accessible on three sides to make control and maintenance easy. The hydraulic section is also easily accessible.

Cooling Capacity

Seasonal energy efficiency rating

[kW]

SEPR HT

CFT100

102.18

5

CFT115

118.93

5.13

CFT130

130.23

5.21

CFT160

166.41

5.11

CFT180

179.47

5.32

CFT200

196.15

5.31

CFT230

240.44

5.54

CFT260

257.05

5.53

CFT280

286.66

5.47

CFT300

308.74

5.32

Data referred to: water temp. in/out: 12/7°C – ambient air temp. 35°C
SEPR HT Data are in accordance with European Regulation (EU) 2016/2281 for eco-design requirements.
The complete technical data can be found in the product brochure.

The CFT chiller series is highly configurable

  • Continuous fan(s) speed control - phase cut type (minimum ambient temperature -8.0°C)
  • Continuous fan(s) speed control - electronic fan(s) (minimum ambient temperature -10.0°C)
  • Electronic thermostatic valve
  • Shut-off valves
  • Anti-freeze heaters
  • Condenser anticorrosion treatment (cataphoresis type)
  • Compressor(s) acoustic shield(s)
  • Single P3 Pump
  • Non ferrous atmospheric water circuit (plastic water tank)
  • Cold water tank configuration
  • No tank configuration
  • No pump configuration
  • Additional atmospheric water tank kit (glycol charge)
  • Double atmospheric water tank kit (glycol charge)
  • Disconnector tank configuration with P2/P3 pump
  • Mechanical water level
  • switch P2/P3 configuration for glycol up to 50%
  • Partial / Full heat recovery
  • Electrical switchboard anti-condensation heater
  • Remote Panel Kit
  • Water connections kit (GAS)
  • Rubber anti-vibration mountings kit
  • Wheels kit